HOW TO SELECT A FLOW METER
When selecting a flow meter, follow the
steps below:
【1】Confirm the properties of the detection fluid
【2】Confirm the purpose of measurement and determine the detection method
【3】Confirm product specifications
【4】Consider cost
【2】Confirm the purpose of measurement and determine the detection method
【3】Confirm product specifications
【4】Consider cost
【1】First, it is necessary to
confirm the properties of detection fluids.
Fluid types
|
Gas, Liquid, Vapor, etc.
|
Density
|
Can be calculated from fluid name, temperature and
pressure
|
Viscosity
|
Required for liquids
|
Electrical conductivity
|
Required for electromagnetic type flow meters
|
Contaminants
|
Air bubbles, mixed-in foreign objects, slurry, etc.
|
Flow range
|
Minimum and maximum flow
|
Fluid temperature
|
Measured in response to the fluid
|
Fluid pressure
|
For pressure-resistance confirmation
|
Pressure loss
|
Measured as necessary
|
【2】Next, clarify the purpose of measurement. At this point, determine a
selectable detection system along with properties such as accuracy and flow
range
【3】Once the detection method has been determined, make a decision while
confirming detailed model specifications.
【4】Finally, compare costs. Because removing a flow meter also takes
time, you must make a decision that not only considers the unit price of the
product, but also considers maintenance time after installation as well as the
cost of set-up or troubleshooting. Generally when the product unit price is
low, frequent maintenance or failure replacement may be required.
COMPARISON OF EACH FLOW METER DETECTION METHOD
[REPRESENTATIVE EXAMPLE]
Ultrasonic | ||||
Liquid
|
Available
|
Available
|
Available
|
Available
|
Gas
|
N/A
|
Available
|
Conditional
|
Available
|
Vapor
|
N/A
|
Conditional
|
N/A
|
Available
|
High temperature support
|
Available
|
Available
|
Available
|
Available
|
Micro flow
|
Conditional
|
N/A
|
Available
|
N/A
|
Medium flow
|
Available
|
Conditional
|
Available
|
Available
|
Large flow
|
Available
|
Available
|
Conditional
|
Available
|
Viscosity
|
Available
|
Available
|
Conditional
|
N/A
|
Slurry
|
Available
|
Available
|
Available
|
Conditional
|
Oil
|
N/A
|
Available
|
Available
|
N/A
|
Accuracy
|
Available
|
Available
|
Available
|
Available
|
Maintainability
|
Available
|
Available
|
Available
|
Available
|
Pressure loss
|
Available
|
Available
|
N/A
|
Conditional
|
Air bubbles
|
Conditional
|
N/A
|
Available
|
Conditional
|